Фильтр
SIPROCESS GA700 – ULTRAMAT 7
-
7MB3010-2CB10-0AB0-Z — ULTRAMAT 7 module for measuring IR-absorbing gases for installation into base unit SIPROCESS GA700 Standard module for Ex-zone for 19 inch rack unit and wall housing Measured component CO2 Smallest measuring range 0 — 10 vpm Largest measuring range 0 — 200 vpm Material: pipes (Stainless steel 1.4571), Sample chamber (aluminum) Reference chamber: Non-flow-type Atmospheric pressure compensation — Module for Wall housing standard (without EN15267 conformity) Assignment-number Base unit — analyzing module (7MB3010-2CB10-0AB0-Z)
-
7MB3010-2CC10-0AA0-Z — ULTRAMAT 7 module for measuring IR-absorbing gases for installation into base unit SIPROCESS GA700 Standard module for Ex-zone for 19 inch rack unit and wall housing Measured component CO2 Smallest measuring range 0 — 20 vpm Largest measuring range 0 — 400 vpm Material: pipes (Stainless steel 1.4571), Sample chamber (aluminum) Reference chamber: Non-flow-type Atmospheric pressure compensation — Module for 19 inch rack unit standard (without EN15267 conformity) Assignment-number Base unit — analyzing module (7MB3010-2CC10-0AA0-Z)
-
7MB3010-2JP20-0AB0-Z — ULTRAMAT 7 module for measuring IR-absorbing gases for installation into base unit SIPROCESS GA700 Standard module for Ex-zone for 19 inch rack unit and wall housing Measured component NH3 (DRY) Smallest measuring range 0 — 10% Largest measuring range 0 -100% Material: pipes (Stainless steel 1.4571), Sample chamber (Tantalum, for cell length 20 to 180 mm) Reference chamber: Non-flow-type Atmospheric pressure compensation — Module for Wall housing standard (without EN15267 conformity) Assignment-number Base unit — analyzing module (7MB3010-2JP20-0AB0-Z)
-
7MB3040-2XX00-0AA0-Z — CALOMAT 7 module for the measurement of gases in binary or quasi-binary gas mixtures for installation into base unit SIPROCESS GA700 (7MB3040-2XX00-0AA0-Z)
-
7MB6121-0CA00-0XX1 — Without Ex-protection, not LDS 6 ДИОДНОЛАЗЕРНЫЙ suitable for connection to CD 6 СПЕКТРОМЕТР, ЦЕНТРАЛЬНЫЙ МОДУЛЬ Ex-variant Measured component: NH3 Application Channel 1: Emission monitoring, non-certified With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel 2: not used Application Channel 3: not used Preset for system language: English (7MB6121-0CA00-0XX1)
-
7MB6121-0CA00-0XX1-Z — Without Ex-protection, not LDS 6 ДИОДНОЛАЗЕРНЫЙ СПЕКТРОМЕТР, ЦЕНТРАЛЬНЫЙ МОДУЛЬ suitable for connection to CD 6 Ex-variant Measured component: NH3 Application Channel 1: Emission monitoring, non-certified With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel 2: not used Application Channel 3: not used Preset for system language: English Application Step 2 Application Step 5 Additional Tag special application (7MB6121-0CA00-0XX1-Z)
-
7MB6121-0GA00-0AX1 — Without Ex-protection, not LDS 6 ДИОДНОЛАЗЕРНЫЙ СПЕКТРОМЕТР, ЦЕНТРАЛЬНЫЙ МОДУЛЬ suitable for connection to CD 6 Ex-variant Measured component: HF Application Channel 1: Emission monitoring, non-certified With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel 2: Emission monitoring, non-certified Application Channel 3: not used Preset for system language: English (7MB6121-0GA00-0AX1)
-
7MB6121-0GA00-0XX1 — Without Ex-protection, not LDS 6 ДИОДНОЛАЗЕРНЫЙ suitable for connection to CD 6 СПЕКТРОМЕТР, ЦЕНТРАЛЬНЫЙ МОДУЛЬ Ex-variant Measured component: HF Application Channel 1: Emission monitoring, non-certified With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel 2: not used Application Channel 3: not used Preset for system language: English (7MB6121-0GA00-0XX1)