Фильтр

SIPROCESS GA700 – ULTRAMAT 7

  • Заполнитель

    7MB3000-0FX00-1BC0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules (7MB3000-0FX00-1BC0-Z)

  • Заполнитель

    7MB3000-3BX00-1BE0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules (7MB3000-3BX00-1BE0-Z)

  • Заполнитель

    7MB3000-3BX00-1BE0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules Wall housing Assembly site 1: prepared for ULTRAMAT 7 module Assembly site 2: Without analyzing module — Without optional module Without optional module Optional module 2.1 (6 analog outputs and add. 6 digital outputs) Optional module 2.1 (6 analog outputs and add. 6 digital outputs) default menu language English default menu language English Ex-Version for operation in Zone 1 and 2 for flammable and non flammable gases acc. IECEx/ATEX II 2G _ Ex pyb db ib op is IIC T4..T3 Gb; (wall housing) — Assignment-number Base unit — analyzing module Gönnheimer Ex px purging unit continuous purging acc. IECEx and ATEX II 2 G; Ex eb db mb ib [pxb] IIC T4 Gb; II 2 D; Ex tb IIIC T130°C [ib] [pxb] Db (7MB3000-3BX00-1BE0-Z)

  • Заполнитель

    7MB3000-3BX01-0BE0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules (7MB3000-3BX01-0BE0-Z)

  • Заполнитель

    7MB3010-2AB10-0AA0-Z — ULTRAMAT 7 module for measuring IR-absorbing gases for installation into base unit SIPROCESS GA700 (7MB3010-2AB10-0AA0-Z)

  • Заполнитель

    7MB3010-2AC10-0AA0-Z — ULTRAMAT 7 module for measuring IR-absorbing gases for installation into base unit SIPROCESS GA700 Standard module for Ex-zone for 19 inch rack unit and wall housing Measured component CO Smallest measuring range 0 — 20 vpm Largest measuring range 0 — 400 vpm Material: pipes (Stainless steel 1.4571), Sample chamber (aluminum) Reference chamber: Non-flow-type Atmospheric pressure compensation — Module for 19 inch rack unit standard (without EN15267 conformity) Assignment-number Base unit — analyzing module (7MB3010-2AC10-0AA0-Z)

  • Заполнитель

    7MB3010-2BC10-0AB0-Z — ULTRAMAT 7 module for measuring IR-absorbing gases for installation into base unit SIPROCESS GA700 Standard module for Ex-zone for 19 inch rack unit and wall housing Measured component CO (SELECTIVE) Smallest measuring range 0 — 20 vpm Largest measuring range 0 — 400 vpm Material: pipes (Stainless steel 1.4571), Sample chamber (aluminum) Reference chamber: Non-flow-type Atmospheric pressure compensation — Module for Wall housing standard (without EN15267 conformity) Assignment-number Base unit — analyzing module (7MB3010-2BC10-0AB0-Z)

  • Заполнитель

    7MB3010-2CB10-0AA0-Z — ULTRAMAT 7 module for measuring IR-absorbing gases for installation into base unit SIPROCESS GA700 (7MB3010-2CB10-0AA0-Z)