Фильтр

SIPROCESS GA700 – ULTRAMAT 7

  • Заполнитель

    7MB2357-0AG06-3PV1-Z — Gas analyzer ultramat 23 for measurement of 2 infrared Components and oxygen conc. TUEV 19″ plug-in unit for mounting in enclosure, gas connections 6 mm stubs, without internal sample gas pump, without separate gas paths (2 channel) 1st component to be measured: CO 1st component to be measured Min. measuring range: CO: 0 to 200 mg/m3 SO2: 0 to 500 mg/m3 NO: 0 to 250 mg/m3 Max. measuring range: CO: 0 to 1250 mg/m3 SO2: 0 to 2500 mg/m3 NO: 0 to 1250 mg/m3 without O2-Sensor . Power supply: AC 230 V, 50 Hz 2nd component to be measured: NO 2nd component to be measured Min. measuring range: 0 to 250 mg/m3 Max. measuring range: 0 to 1250 mg/m3 Operator’s software and documentation in english Without O2 Approved acc. EN 15267, IR Meas. range in mg/m3 (7MB2357-0AG06-3PV1-Z)

  • Заполнитель

    7MB2357-0CP06-3AA1 — Gas analyzer ultramat 23 for measurement of 2 infrared Components and oxygen conc. TUEV 19″ plug-in unit for mounting in enclosure, gas connections 6 mm stubs, without internal sample gas pump, without separate gas paths (2 channel) 1st component to be measured: CO2 1st component to be measured Min. measuring range: 0 to 5% Max. measuring range: 0 to 25% without O2-Sensor . Power supply: AC 230 V, 50 Hz 2nd component to be measured: CO 2nd component to be measured Min. measuring range: CO: 0 to 50 mg/m3 Max. measuring range: CO: 0 to 500 mg/m3 Operator’s software and documentation in english (7MB2357-0CP06-3AA1)

  • Заполнитель

    7MB2357-0PA06-3NS1 — Gas analyzer ultramat 23 for measurement of 2 infrared Components and oxygen conc. TUEV 19″ plug-in unit for mounting in enclosure, gas connections 6 mm stubs, without internal sample gas pump, without separate gas paths (2 channel) 1st component to be measured: NO 1st component to be measured Min. measuring range: 0 to 50 mg/m³ Max. measuring range: 0 to 500 mg/m³ without O2-Sensor . Power supply: AC 230 V, 50 Hz 2nd component to be measured: SO2 2nd component to be measured Min. measuring range: 0 to 50 mg/m3 Max. measuring range: 0 to 1250 mg/m3. Parallel Meas. of SO2 and NO2 with UV Fotometer Operator’s software and documentation in english (7MB2357-0PA06-3NS1)

  • Заполнитель

    7MB2358-0AK86-3NH1-Z — Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen conc. TUEV (7MB2358-0AK86-3NH1-Z)

  • Заполнитель

    7MB2421-0BA10-1AA1-Z — Pipe with 6 mm outer diameter FIDAMAT 6 АНАЛИЗАТОР 19″ ДЛЯ МОНТАЖА В ШКАФ Without pump, for sample gas БЕЗ ДОПОЛНИТЕЛЬНОЙ ЭЛЕКТРОНИКИ with overpressure ДОКУМЕНТАЦИЯ И ПРОГРАММНОЕ ОБЕСПЕЧЕНИЕ НА АНГЛИЙСКОМ ЯЗЫКЕ With connnection for combustion air 1-channel version AC 200 V to 240 V, 48 to 63 Hz H2 . Clean for O2-Service (specially cleaned gas path) (7MB2421-0BA10-1AA1-Z)

  • Заполнитель

    7MB2531-0AN50-1BF1-Z — Stainless steel, mat. No. CALOMAT 62 АНАЛИЗАТОР ДЛЯ ПОЛЕВОГО МОНТАЖА 1.4571; non-flow-type reference chamber, 1/8″-27 NPT (Purging gas stub 10 mm) H2 in N2 Smallest measuring range: 100 to 99 %, largest measuring range: 100 to 0 % (sample gas component) Without additional electronics AC 200 to 240 V, 48 to 63 Hz With (max. 80°C) Certificate ATEX continuous purging, ATEX II 2G Ex px ia[ia] IIC T4 Gb English Ex purge unit for use in ATEX or IECEx Zone 1 or Zone 2 acc. II 2(1)G _ Ex eb mb ib [ib pxb] [ia Ga] IIC T4 Gb consisting of an Ex p control unit for continuous operating flow and an Ex e control station with bypass-key-switch; 100 VAC to 230 VAC according IECEx and ATEX II 2(1)G _ Ex eb mb ib [ib pxb] [ia Ga] IIC T4 Gb (7MB2531-0AN50-1BF1-Z)

  • Заполнитель

    7MB3000-0BB00-1BC0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules (7MB3000-0BB00-1BC0-Z)

  • Заполнитель

    7MB3000-0BB00-1BC0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules 19 inch-rack Assembly site 1: prepared for ULTRAMAT 7 module Assembly site 2: prepared for ULTRAMAT 7 module — Without optional module Without optional module Optional module 2.1 (6 analog outputs and add. 6 digital outputs) Optional module 2.1 (6 analog outputs and add. 6 digital outputs) default menu language English default menu language English Ex-Version for operation in Zone 2 for flammable and non flammable gases, acc. IECEx/ATEX II 3G _ Ex ec db ic nC op is IIC T4 Gc (19″ rack) — Assignment-number Base unit — analyzing module (7MB3000-0BB00-1BC0-Z)