  • SIPROCESS GA700 – ULTRAMAT 7

    7MB2358-0AK86-3NH1-Z — Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen conc. TUEV

  • SIPROCESS GA700 – ULTRAMAT 7

    7MB2421-0BA10-1AA1-Z — Pipe with 6 mm outer diameter FIDAMAT 6 АНАЛИЗАТОР 19″ ДЛЯ МОНТАЖА В ШКАФ Without pump, for sample gas БЕЗ ДОПОЛНИТЕЛЬНОЙ ЭЛЕКТРОНИКИ with overpressure ДОКУМЕНТАЦИЯ И ПРОГРАММНОЕ ОБЕСПЕЧЕНИЕ НА АНГЛИЙСКОМ ЯЗЫКЕ With connnection for combustion air 1-channel version AC 200 V to 240 V, 48 to 63 Hz H2 . Clean for O2-Service (specially cleaned gas path)

  • SIPROCESS GA700 – ULTRAMAT 7

    7MB2531-0AN50-1BF1-Z — Stainless steel, mat. No. CALOMAT 62 АНАЛИЗАТОР ДЛЯ ПОЛЕВОГО МОНТАЖА 1.4571; non-flow-type reference chamber, 1/8″-27 NPT (Purging gas stub 10 mm) H2 in N2 Smallest measuring range: 100 to 99 %, largest measuring range: 100 to 0 % (sample gas component) Without additional electronics AC 200 to 240 V, 48 to 63 Hz With (max. 80°C) Certificate ATEX continuous purging, ATEX II 2G Ex px ia[ia] IIC T4 Gb English Ex purge unit for use in ATEX or IECEx Zone 1 or Zone 2 acc. II 2(1)G _ Ex eb mb ib [ib pxb] [ia Ga] IIC T4 Gb consisting of an Ex p control unit for continuous operating flow and an Ex e control station with bypass-key-switch; 100 VAC to 230 VAC according IECEx and ATEX II 2(1)G _ Ex eb mb ib [ib pxb] [ia Ga] IIC T4 Gb

  • SIPROCESS GA700 – ULTRAMAT 7

    7MB3000-0BB00-1BC0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules

  • SIPROCESS GA700 – ULTRAMAT 7

    7MB3000-0BB00-1BC0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules 19 inch-rack Assembly site 1: prepared for ULTRAMAT 7 module Assembly site 2: prepared for ULTRAMAT 7 module — Without optional module Without optional module Optional module 2.1 (6 analog outputs and add. 6 digital outputs) Optional module 2.1 (6 analog outputs and add. 6 digital outputs) default menu language English default menu language English Ex-Version for operation in Zone 2 for flammable and non flammable gases, acc. IECEx/ATEX II 3G _ Ex ec db ic nC op is IIC T4 Gc (19″ rack) — Assignment-number Base unit — analyzing module

  • SIPROCESS GA700 – ULTRAMAT 7

    7MB3000-0FX00-1BC0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules

  • SIPROCESS GA700 – ULTRAMAT 7

    7MB3000-3BX00-1BE0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules

  • SIPROCESS GA700 – ULTRAMAT 7

    7MB3000-3BX00-1BE0-Z — Gas analyzer SIPROCESS GA700, base unit for installation of measuring modules Wall housing Assembly site 1: prepared for ULTRAMAT 7 module Assembly site 2: Without analyzing module — Without optional module Without optional module Optional module 2.1 (6 analog outputs and add. 6 digital outputs) Optional module 2.1 (6 analog outputs and add. 6 digital outputs) default menu language English default menu language English Ex-Version for operation in Zone 1 and 2 for flammable and non flammable gases acc. IECEx/ATEX II 2G _ Ex pyb db ib op is IIC T4..T3 Gb; (wall housing) — Assignment-number Base unit — analyzing module Gönnheimer Ex px purging unit continuous purging acc. IECEx and ATEX II 2 G; Ex eb db mb ib [pxb] IIC T4 Gb; II 2 D; Ex tb IIIC T130°C [ib] [pxb] Db