• 7MB1957-0CB11-3AC0-Z — Standardized SIEMENS Continuous Emission Monitoring System (CEMS), compliant with European emission control guidelines Set CEM CERT, steel cabinet (2100x800x800), sample gas connections left, cable inlet on top, with sample conditioning, swing frame with up to 3 slots for 19 inch analyzers, with cabinet light, incl. side walls and front door Sample Probe Bühler GAS 222 (7MB19432FBxx) for dust load up to 2 g per m3, incl. sample tube, 1 m length, temp. max. 600 C, with weather protection hood Cabinet fan with filter, mounted in side wall, with adjustable thermostate With electrical heater integrated in cabinet, allowable ambient temperature, minus 5 C (Rittal cab.) or minus 15 C (GRP cab.) Circuit breakers for 2-pole protection Type: Compressor gas cooler Bühler RC1.2, incl. 2 heat exchangers, mounted in series, including peristaltic pumps for enhanced cooling tasks Without NOx converter Power supply, 230 / 400V, (-15%, +10%), 50 or 60 Hz incl. main switch, 3-phase not assigned Condensate vessel, corrosion resistant with level control Set CEM CERT II: Analyzer position 1: Preparation for Ultramat 23 (7MB23x5/7MB23x7/7MB23x8); the analyzer has to be ordered separately To be considered: For 7MB233x QAL1 compliance only ensured at base of MCERTs certificate Set CEM CERT II: Analyzer position 3: Preparation for Ultramat 23 (7MB23x5/7MB23x7/7MB23x8); the analyzer has to be ordered separately To be considered: For 7MB233x QAL1 compliance only ensured at base of MCERTs certificate Prep. for one additional LDS 6 central unit (7MB6121). The LDS 6 central unit plus CD6 sensor pair have to be ordered separately Protection (25A) and controler for heated sample line, up to 50 meter length, the heated sample line needs to be ordered with MLFB 7MB1943-2AA31 External solenoid valve for AUTOCAL-function of the Ultramat 23; max. qty.: 1 Communication Interface of Set: MODBUS TCP Technical documentation of SIEMENS CEMS and implemented analyzers, language: English

  • 7MB1957-0CB11-3BC0-Z — Standardized SIEMENS Continuous Emission Monitoring System (CEMS), compliant with European emission control guidelines

  • 7MB1957-0CB11-3BC0-Z — Standardized SIEMENS Continuous Emission Monitoring System (CEMS), compliant with European emission control guidelines Set CEM CERT, steel cabinet (2100x800x800), sample gas connections left, cable inlet on top, with sample conditioning, swing frame with up to 3 slots for 19 inch analyzers, with cabinet light, incl. side walls and front door Sample Probe Bühler GAS 222 (7MB19432FBxx) for dust load up to 2 g per m3, incl. sample tube, 1 m length, temp. max. 600 C, with weather protection hood Cabinet fan with filter, mounted in side wall, with adjustable thermostate With electrical heater integrated in cabinet, allowable ambient temperature, minus 5 C (Rittal cab.) or minus 15 C (GRP cab.) Circuit breakers for 2-pole protection Type: Compressor gas cooler Bühler RC1.2, incl. 2 heat exchangers, mounted in series, including peristaltic pumps for enhanced cooling tasks NOx converter, version Bühler BüNOx Power supply, 230 / 400V, (-15%, +10%), 50 or 60 Hz incl. main switch, 3-phase not assigned Condensate vessel, corrosion resistant with level control Set CEM CERT II: Analyzer position 1: Preparation for Ultramat 23 (7MB23x5/7MB23x7/7MB23x8); the analyzer has to be ordered separately To be considered: For 7MB233x QAL1 compliance only ensured at base of MCERTs certificate Protection (25A) and controler for heated sample line, up to 50 meter length, the heated sample line needs to be ordered with MLFB 7MB1943-2AA31 External solenoid valve for AUTOCAL-function of the Ultramat 23; max. qty.: 1 Communication Interface of Set: MODBUS TCP Technical documentation of SIEMENS CEMS and implemented analyzers, language: English

  • 7MB1957-0CC11-2CC0-Z — Standardized SIEMENS Continuous Emission Monitoring System (CEMS), compliant with European emission control guidelines

  • 7MB1957-0CC11-3BC0-Z — Standardized SIEMENS Continuous Emission Monitoring System (CEMS), compliant with European emission control guidelines Set CEM CERT, steel cabinet (2100x800x800), sample gas connections left, cable inlet on top, with sample conditioning, swing frame with up to 3 slots for 19 inch analyzers, with cabinet light, incl. side walls and front door Sample Probe Bühler GAS 222 (7MB19432FBxx) for dust load up to 2 g per m3, incl. sample tube, 1 m length, temp. max. 600 C, with weather protection hood Efficient air conditioner for steel cabinet, integrated in side wall, adjustment with thermostate With electrical heater integrated in cabinet, allowable ambient temperature, minus 5 C (Rittal cab.) or minus 15 C (GRP cab.) Circuit breakers for 2-pole protection Type: Compressor gas cooler Bühler RC1.2, incl. 2 heat exchangers, mounted in series, including peristaltic pumps for enhanced cooling tasks NOx converter, version Bühler BüNOx Power supply, 230 / 400V, (-15%, +10%), 50 or 60 Hz incl. main switch, 3-phase not assigned Condensate vessel, corrosion resistant with level control Set CEM CERT II: Analyzer position 1: Preparation for Ultramat 23 (7MB23x5/7MB23x7/7MB23x8); the analyzer has to be ordered separately To be considered: For 7MB233x QAL1 compliance only ensured at base of MCERTs certificate Protection (25A) and controler for heated sample line, up to 50 meter length, the heated sample line needs to be ordered with MLFB 7MB1943-2AA31 External solenoid valve for AUTOCAL-function of the Ultramat 23; max. qty.: 1 Signal analogique, doublé, 1er signal, séparé galvaniquement, max. 600 Ohm, 1 x par signal analogique Signal analogique, doublé, 2ème signal, séparé galvaniquement, max. 600 Ohm, 1 x par signal analogique Signal analogique, doublé, 3ème signal, séparé galvaniquement, max. 600 Ohm, 1 x par signal analogique Signal analogique, doublé, 4ème signal, séparé galvaniquement, max. 600 Ohm, 1 x par signal analogique Signal analogique, doublé, 5ème signal, séparé galvaniquement, max. 600 Ohm, 1 x par signal analogique Signal analogique, doublé, 6ème signal, séparé galvaniquement, max. 600 Ohm, 1 x par signal analogique Technical documentation of SIEMENS CEMS and implemented analyzers, language: English

  • 7MB1957-0GB01-2BC0-Z — Standardized SIEMENS Continuous Emission Monitoring System (CEMS), compliant with European emission control guidelines Set CEM CERT, steel cabinet (2100x800x800), sample gas connections left, cable inlet on top, with sample conditioning, swing frame with up to 3 slots for 19 inch analyzers, with cabinet light, incl. side walls and front door Twin probe, type Buehler, based on version GAS 222, with connectors for 2 heated sample lines, for dust load up to 2 g per m3, incl. sample tube, 1 m length, temp. max. 600 C, with weather protection hood Cabinet fan with filter, mounted in side wall, with adjustable thermostate Without electrical heater Circuit breakers for 2-pole protection Type: EGK2-19, incl. 2 heat exchangers, mounted in series, including peristaltic pumps for enhanced cooling tasks NOx converter, version Bühler BüNOx Power supply, 230 / 400V, (-15%, +10%), 50 or 60 Hz incl. main switch, 3-phase not assigned Analyzer position 1: Preparation for Ultramat 23 (7MB23x5/7MB23x7/7MB23x8); the analyzer has to be ordered separately To be considered: For 7MB233x QAL1 compliance only ensured at base of MCERTs certificate Protection (25A) and controler for heated sample line, up to 50 meter length, the heated sample line needs to be ordered with MLFB 7MB1943-2AA31 External solenoid valve for AUTOCAL-function of the Ultramat 23; max. qty.: 1 Technical documentation of SIEMENS CEMS and implemented analyzers, language: English

  • 7MB2001-0EA00-1DA1-Z — Pipe with 6 mm outer diameter OXYMAT 61 АНАЛИЗАТОР КИСЛОРОДА 19″ ДЛЯ МОНТАЖА В ШКАФ 5 % reference gas pressure 3000 ДОКУМЕНТАЦИЯ И ПРОГРАММНОЕ hPa ОБЕСПЕЧЕНИЕ НА АНГЛИЙСКОМ ЯЗЫКЕ СПЕЦИАЛЬНАЯ ОЧИСТКА ПРОВОДКИ ГАЗА ДЛЯ О2 . . . AC 200 to 240 V, 48 to 63 Hz With sample gas monitoring (incl. flow indicator and pressure switch) Without AUTOCAL function

  • 7MB2041-0AA10-1AA1 — ZrO2: Catalytically active cell ГАЗОВЫЙ АНАЛИЗАТОР КИСЛОРОДА (CAC) МАЛЫХ КОНЦЕНТРАЦИЯ, 19″ ШКАФНОЕ ИСПОЛНЕНИЕ High pressure, without pressure regulator (2000 hPa) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English